Maxim-integrated 73M2901CE AT Command Manuel d'utilisateur Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
73M2901CE AT Command User Guide UG_2901CE_027
34 Rev. 2.0
4.4.47 S46 – Cadence A Max Off Time of Busy
(Default = 15)
The value of this register sets the duration of the primary cadence maximum busy signal OFF time in
units of 40ms.
4.4.48 S47 – Cadence B Min On Time of Busy
(Default = 0)
The value of this register sets the duration of the alternate cadence minimum busy signal ON time in units
of 40ms.
4.4.49 S48 – Cadence B Max On Time of Busy
(Default = 0)
The value of this register sets the duration of the alternate cadence maximum busy signal ON time in
units of 40ms.
4.4.50 S49 – Cadence B Min Off Time of Busy
(Default = 0)
The value of this register sets the duration of the alternate cadence minimum busy signal OFF time in
units of 40ms.
4.4.51 S50 – Cadence B Max Off Time of Busy
(Default = 0)
The value of this register sets the duration of the alternate cadence maximum busy signal OFF time in
units of 40ms.
4.4.52 S51 – Cadence A Min On Time of Ring
(Default = 40)
The value of this register sets the duration of the primary cadence minimum ring ON time in units of
40ms.
4.4.53 S52 – Cadence A Max On Time of Ring
(Default = 60)
The value of this register sets the duration of the primary cadence maximum ring ON time in units of
40ms.
4.4.54 S53 – Cadence A Min Off Time of Ring
(Default = 80)
The value of this register sets the duration of the primary cadence minimum ring OFF time in units of
40ms.
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 51 52

Commentaires sur ces manuels

Pas de commentaire