MAXQ Family Users Guide:
MAXQ8913 Supplement
25-6
25.3.7 UROM_moveBP
Notes:
Before calling this function, DPC should be set appropriately to configure BP[OFFS] for byte or word mode.
The address passed to this function should be based on the data memory mapping for the utility ROM, as shown
in Figure 25-1. When a byte mode address is used, CDA0 must be set appropriately to access either the upper or
lower half of program flash/ROM memory.
This function automatically refreshes the data pointer before reading the byte/word value.
25.3.8 UROM_moveBPinc
Notes:
Before calling this function, DPC should be set appropriately to configure BP[OFFS] for byte or word mode.
The address passed to this function should be based on the data memory mapping for the utility ROM, as shown
in Figure 25-1. When a byte mode address is used, CDA0 must be set appropriately to access either the upper or
lower half of program flash/ROM memory.
This function automatically refreshes the data pointer before reading the byte/word value.
25.3.9 UROM_moveBPdec
Notes:
Before calling this function, DPC should be set appropriately to configure BP[OFFS] for byte or word mode.
The address passed to this function should be based on the data memory mapping for the utility ROM, as shown
in Figure 25-1. When a byte mode address is used, CDA0 must be set appropriately to access either the upper or
lower half of program flash/ROM memory.
This function automatically refreshes the data pointer before reading the byte/word value.
Function:
UROM_moveBPinc
Summary:
Reads the byte/word value pointed to by BP[OFFS], then increments OFFS.
Inputs:
DP[1]: Address to read from.
Outputs:
GR: Data byte/word read.
OFFS is incremented.
Destroys:
None.
Function:
UROM_moveBPdec
Summary:
Reads the byte/word value pointed to by BP[OFFS], then decrements OFFS.
Inputs:
DP[1]: Address to read from.
Outputs:
GR: Data byte/word read.
OFFS is decremented.
Destroys:
None.
Function:
UROM_moveBP
Summary:
Reads the byte/word value pointed to by BP[OFFS].
Inputs:
BP[OFFS]: Address to read from.
Outputs:
GR: Data byte/word read.
Destroys:
None.