Maxim-integrated MAX15301 PMBus Command Set Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Maxim-integrated MAX15301 PMBus Command Set. Maxim Integrated MAX15301 PMBus Command Set User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent
licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000
© 2014 Maxim Integrated Products, Inc. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.
MAX15301 PMBus Command Set
User’s Guide
Rev 1; 10/14
Vue de la page 0
1 2 3 4 5 6 ... 52 53

Résumé du contenu

Page 1 - User’s Guide

Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circ

Page 2 - Part Number Differences

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 10 of 53 Output Voltage Related Commands VOUT_MODE Reference: Standard Command Lockable: No C

Page 3 - Table of Contents

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 11 of 53 VOUT_TRIM VOUT_CAL_OFFSET, and the result is sent to the control loop as the output vo

Page 4

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 12 of 53 VOUT_MARGIN_HIGH Description/Notes: See Section 13.6 of the PMBus Specification Part I

Page 5

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 13 of 53 VOUT_TRANSITION_RATE Reference: Standard Command Lockable: Yes Command Code: 0x27 For

Page 6 - Rev 1 Page 6 of 53

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 14 of 53 VOUT_DROOP accurate adaptive voltage positioning results with the VOUT_DROOP command.

Page 7 - ON_OFF_CONFIG

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 15 of 53 Switching Frequency and PWM Commands FREQUENCY_SWITCH Reference: Standard Command Loc

Page 8

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 16 of 53 INTERLEAVE ADDR1 pins, unless a non-zero value of INTERLEAVE has been written to the U

Page 9 - VIN_OFF

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 17 of 53 POWER_GOOD_OFF Reference: Standard Command Lockable: Yes Command Code: 0x5F Format: U

Page 10 - VOUT_TRIM

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 18 of 53 TON_RISE Reference: Standard Command Lockable: Yes Command Code: 0x61 Format: Linear

Page 11 - VOUT_MARGIN_HIGH

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 19 of 53 TOFF_FALL Reference: Standard Command Lockable: Yes Command Code: 0x65 Format: Linear

Page 12 - VOUT_MARGIN_LOW

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 2 of 53 Introduction Maxim Integrated InTune™ digital power products util

Page 13 - VOUT_DROOP

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 20 of 53 Fault Related Commands CLEAR_FAULTS Reference: Standard Command Lockable: Yes Command

Page 14

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 21 of 53 VOUT_OV_FAULT_RESPONSE Reference: Standard Command Lockable: Yes Command Code: 0x41 F

Page 15 - INTERLEAVE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 22 of 53 VOUT_UV_FAULT_LIMIT VOUT_COMMAND x 0.85, unless a specific value has been written to t

Page 16 - POWER_GOOD_ON

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 23 of 53 IOUT_OC_FAULT_RESPONSE Reference: Standard Command Lockable: Yes Command Code: 0x47

Page 17 - TON_DELAY

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 24 of 53 OT_FAULT_LIMIT temperature signal instead. In addition to the PMBus-programmable OT_FA

Page 18 - TOFF_DELAY

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 25 of 53 OT_WARN_LIMIT Reference: Standard Command Lockable: Yes Command Code: 0x51 Format: Li

Page 19 - TOFF_FALL

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 26 of 53 VIN_OV_FAULT_RESPONSE 10 Stop regulating immediately, delay for the time specified in

Page 20 - Fault Related Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 27 of 53 VIN_UV_FAULT_RESPONSE restart according to bits [5:3]. 11 Stop regulating immediate

Page 21 - VOUT_UV_FAULT_LIMIT

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 28 of 53 Unit Status Commands STATUS_BYTE Reference: Standard Command Lockable: N/A Command Co

Page 22 - IOUT_OC_FAULT_LIMIT

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 29 of 53 STATUS_INPUT Reference: Standard Command Lockable: N/A Command Code: 0x7C Format: Bit

Page 23 - OT_FAULT_LIMIT

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 3 of 53 Table of Contents Introduction ...

Page 24 - OT_FAULT_RESPONSE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 30 of 53 Telemetry Commands READ_VIN Reference: Standard Command Lockable: N/A Command Code: 0

Page 25 - VIN_OV_FAULT_RESPONSE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 31 of 53 READ_TEMPERATURE_1 Reference: Standard Command Lockable: N/A Command Code: 0x8D Forma

Page 26 - VIN_UV_FAULT_RESPONSE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 32 of 53 READ_FREQUENCY Reference: Standard Command Lockable: N/A Command Code: 0x95 Format: L

Page 27

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 33 of 53 PMB_VALUES <POWER_GOOD_OFF position="30" Type="Float" NumElem=&

Page 28 - Unit Status Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 34 of 53 Calibration Commands IOUT_CAL_GAIN Reference: Standard Command Lockable: Yes Command

Page 29 - STATUS_CML

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 35 of 53 EXT_TEMP_CAL (MAX15301AA01) Byte # Data Byte Name Units Description 0 Ideality Facto

Page 30 - Telemetry Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 36 of 53 Device Identification Commands CAPABILITY Reference: Standard Command Lockable: N/A C

Page 31 - READ_DUTY_CYCLE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 37 of 53 MFR_MODEL Reference: Standard Command Lockable: Yes Command Code: 0x9A Format: ASCII

Page 32 - PMB_VALUES

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 38 of 53 MFR_SERIAL Reference: Standard Command Lockable: Yes Command Code: 0x9E Format: ASCII

Page 33

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 39 of 53 Security Commands WRITE_PROTECT Reference: Standard Command Lockable: Yes Command Cod

Page 34 - Calibration Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 4 of 53 VOUT_UV_FAULT_LIMIT ...

Page 35 - EXT_TEMP_CAL (MAX15301AA02)

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 40 of 53 MANUF_LOCK Reference: Maxim Specific Lockable: Yes Command Code: 0xE1 Format: Direct

Page 36 - PMBUS_REVISION

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 41 of 53 USER_CONF memory value of USER_LOCK, then the MAX15301 will ignore attempts to write d

Page 37 - MFR_DATE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 42 of 53 SECURITY_LEVEL Reference: Maxim Specific Lockable: N/A Command Code: 0xE6 Format: Dir

Page 38 - IC_DEVICE_REV

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 43 of 53 Memory and Storage Commands STORE_DEFAULT_ALL Reference: Standard Command Lockable: Y

Page 39 - Security Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 44 of 53 STORE_DEFAULT_ALL NLSS_DATA This command is stored in volatile memory only. Wait at l

Page 40 - USER_CONF

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 45 of 53 STORE_USER_ALL the RESTORE_USER_ALL command. In general, when the STORE_USER_ALL comma

Page 41 - USER_PASSWD

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 46 of 53 RESTORE_USER_ALL Reference: Standard Command Lockable: Yes Command Code: 0x16 Format:

Page 42 - SECURITY_LEVEL

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 47 of 53 STRAP_DISABLE Reference: Maxim Specific Lockable: Yes Command Code: 0xDC Format: Bit

Page 43 - Memory and Storage Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 48 of 53 Control Loop Commands ADAPTIVE_MODE Reference: Maxim Specific Lockable: Yes Command C

Page 44 - STORE_USER_ALL

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 49 of 53 FEEDBACK_EFFORT Reference: Maxim Specific Lockable: Yes Command Code: 0xD3 Format: Li

Page 45

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 5 of 53 CAPABILITY ...

Page 46 - RESTORE_MAXIM_ALL

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 50 of 53 COMP_MODEL Reference: Maxim Specific Lockable: Yes Command Code: 0xDB Format: Linear

Page 47 - STRAP_DISABLE

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 51 of 53 DEADTIME_GCTRL 6 TDF (LSB) Signed Integer AGD system falling edge deadtime target valu

Page 48 - Control Loop Commands

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 52 of 53 DEADTIME_GCTRL 255 -1200 Note: the default setting is LXDAC = 15 and this value shoul

Page 49 - LOOP_CONFIG

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 53 of 53 ZETA_P Wait at least 500μs for execution after sending the ZETA_P command b

Page 50 - DEADTIME_GCTRL

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 6 of 53 Trademarks ...

Page 51

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 7 of 53 On, Off, and Margin Testing Related Commands OPERATION Reference: Standard Command Loc

Page 52

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 8 of 53 ON_OFF_CONFIG Reference: Standard Command Lockable: Yes Command Code: 0x02 Format: Bit

Page 53 - Revision History

MAX15301 PMBus Command Set User’s Guide Rev 1 Page 9 of 53 VIN_OFF Reference: Standard Command Lockable: Yes Command Code: 0x36 Format: Linear Da