MAX15301 PMBus Command Set User’s Guide
Rev 1 Page 17 of 53
POWER_GOOD_OFF
Reference:
Lockable:
Yes
Command Code:
Format:
Unsigned integer mantissa
Data Bytes:
Units:
V
Transfer:
Factory Value:
0x0F99 (see Description)
Description/Notes:
See Section 15.32.2 of the PMBus Specification Part II.
POWER_GOOD_OFF mantissa data sent to and from the MAX15301 must be divided by 4096 to
determine the actual voltage value, according to the fixed value of VOUT_MODE
.
In the MAX15301, there are seven possible output voltage ranges based on seven corresponding
internal feedback divider taps. The MAX15301 hardware has 8-bit resolution for the power-good
threshold within each of these seven ranges.
The desired value of POWER_GOOD_OFF is retained in memory, regardless of limitations imposed by
the feedback divider range and the 8-bit fault limit resolution, but the read-back value is based on
actual hardware register settings.
The factory value of 0x0F99 (0.980V) will be overridden during initialization to
VOUT_COMMAND x 0.93, unless a specific value has been written to the User Store.
TON_DELAY
Reference:
Lockable:
Yes
Command Code:
Format:
Linear
Data Bytes:
Units:
ms
Transfer:
Factory Value:
0xCA80 (see Description)
Description/Notes:
See Section 16.1 of the PMBus Specification Part II.
The TON_DELAY command sets the delay time between a valid enable condition and the beginning of
the output ramp to regulation at VOUT_COMMAND
. The nominal factory value is 5ms.
An 8-bit timer with approximately 570μs resolution allows for delay times from ≈1ms to ≈145ms.