MAX15301 PMBus Command Set User’s Guide
Rev 1 Page 11 of 53
VOUT_TRIM
VOUT_CAL_OFFSET, and the result is sent to the control loop as the output voltage setpoint.
The value of VOUT_TRIM is not subtracted from READ_VOUT, so nonzero VOUT_TRIM values will
result in a difference between VOUT_COMMAND and READ_VOUT.
This command is intended to allow an end user of a PMBus device to tailor a specific supply to the
performance requirements of a specific load device, while retaining use of a “nominal” voltage
setpoint for all similar load devices.
VOUT_CAL_OFFSET
See Section 13.4 of the PMBus Specification Part II.
In the MAX15301, the value of VOUT_CAL_OFFSET is summed with the value of VOUT_COMMAND
and VOUT_TRIM, and the result is sent to the control loop as the output voltage setpoint.
The value of VOUT_CAL_OFFSET is subtracted from READ_VOUT, so VOUT_CAL_OFFSET values never
result in a difference between VOUT_COMMAND and READ_VOUT.
This command is intended to allow a PMBus device manufacturer or an end user to calibrate the
output voltage of a module (or other power-supply assembly) to match an external reference
instrument during their final-test process.
VOUT_MAX
Unsigned integer mantissa
See Section 13.5 of the PMBus Specification Part II.
VOUT_MAX mantissa data sent to and from the MAX15301 must be divided by 4096 to determine the
actual voltage value, according to the fixed value of VOUT_MODE
.
The factory value of 0x0001 (0.244mV) will be ov
erridden during initialization to
VOUT_COMMAND x 1.10, unless a specific value has been written to the User Store.
VOUT_MARGIN_HIGH
Unsigned integer mantissa