7.2.6 – Temperature Control Register (TEMPCN)
Register Address: M2 [0Bh]
The Temperature Control register TEMPCN configures and enables internal die temperature and two external remote
diodes temperatures. Internal Temperature, external diode 0 and external diode 1 temperatures have dedicated data
buffers 22, 21 and 20 respectively. The DS4830 ADC Controller forces current in the diode and integrates voltage across
diode. After integration the ADC Controller measured voltage on ADC and convert measured voltage in temperature.
Reserved. The user should write 0 to these bits.
Internal Temperature Interrupt Enable: Setting this bit to ‘1’ will enable an interrupt generation
on completion of an internal temperature conversion.
External Diode 0 Temperature Interrupt Enable: Setting this bit to ‘1’ will enable an interrupt
generation on completion of an external diode 0 temperature conversion.
External Diode 1 Temperature Interrupt Enable: Setting this bit to ‘1’ will enable an interrupt
generation on completion of an external diode 1 temperature conversion.
Reserved. The user should write 0 to this bit.
External Diode 1 Temperature Data Align. Setting this bit to ‘1’ configures external diode 1
temperature conversion data in left aligned mode. Setting this bit to ‘0’ configures external diode
1 temperature conversion data in right aligned mode.
External Diode 0 Temperature Data Align. Setting this bit to ‘1’ configures external diode 0
temperature conversion data in left aligned mode. Setting this bit to ‘0’ configures external diode
0 temperature conversion data in right aligned mode.
Internal Temperature Data Align. Setting this bit to ‘1’ configures internal temperature
conversion data in left aligned mode. Setting this bit to ‘0’ configures internal temperature
conversion data in right aligned mode.
Reserved. The user should write 0 to this bit.
External Diode 1 Temperature Enable. Setting this bit to ‘1’ initiates external diode 1
temperature conversion. The external diode 1 temperature typical conversion time is 4.1msec.
After external diode 1 temperature conversion result is available in data buffer 20.
External Diode 0 Temperature Enable. Setting this bit to ‘1’ initiates external diode 0
temperature conversion. The external diode 0 temperature typical conversion time is 4.1msec.
After external diode 0 temperature conversion result is available in data buffer 21.
Internal Temperature Enable. Setting this bit to ‘1’ initiates internal temperature conversion.
The internal temperature typical conversion time is 4.1msec. After internal temperature
conversion result is available in data buffer 22.
7.2.7 – External Temperature Slope Control Register (ETS)
Register Address: M1 [16h]
The ETS register sets changes the slope of external temperature measurements to compensate for changes in diode
ideality factor. The DS4830 is factory calibrated to work with a diode connected 2N3904 NPN transistor.