DS4830A User’s Guide
61
7.2.8 – Temperature Control Register (TEMPCN)
The Temperature Control register TEMPCN configures and enables internal die temperature. The Internal
Temperature has a dedicated data buffer at address 22. The DS4830A ADC controller forces current into the internal
diode and integrates voltage across diode. After integration the voltage is measured at ADC and the voltage is
converted into temperature.
Reserved. The user should not write to these bits.
Internal Temperature Interrupt Enable: Setting this bit to ‘1’ enables an interrupt
generation on completion of an internal temperature conversion.
Reserved. The user should not write to these bits.
Internal Temperature Data Align. Setting this bit to ‘1’ configures internal temperature
conversion data in left aligned mode. Setting this bit to ‘0’ configures internal temperature
conversion data in right aligned mode.
Reserved. The user should not write to these bits.
Internal Temperature Enable. Setting this bit to ‘1’ initiates internal temperature
conversion. The internal temperature typical conversion time is 42µs for default ADC clock.
After internal temperature conversion, result is available in data buffer 22.
7.2.9 – Average and Reference Control Register (REFAVG)
Reserved. The user should not write to these bits.
Internal Reference Control: Setting this bit to ‘1’ outputs the ADC internal reference at
GP1 (Pin no 6, Port2.1).
Internal Reference Control: Setting this bit to ‘1’ enables the ADC internal reference and
setting this bit to ‘0’ disables the ADC internal reference.
Reserved. The user should not write to these bits.
Internal Die Temperature Sample Average Control Register: These bits configure the
number of Internal Die Temperature samples to be averaged.
Number of Samples for Averaging
SH1 Sample Average Control Register: These bits configure the number of SH1 samples
to be averaged.
Number of Samples for Averaging
SH0 Sample Average Control Register: These bits configure the number of SH0 samples
to be averaged.
Number of Samples for Averaging